Skip to content
Diesel Generators · Cummins

Cummins-powered generators: 27.5 to 1875 kVA

FOGEN generator sets built on Cummins engines from DCEC, CCEC and Cummins USA, with Stamford, Mecc Alte or FOGEN alternators and DeepSea DSE6020 controllers with AMF as standard.

Overview

What this range delivers

Sixty-two build variants across 50 and 60 Hz: open-frame and silent-canopy sets from 22 kW to 1260 kW prime, moving into 20 and 40 ft containers at the top of the range.

22 to 1260 kW prime

From the compact 4B3.9 four-cylinder to the KTA50 V16, at 50 and 60 Hz.

DeepSea DSE6020

AMF mains monitoring as standard; ComAp controllers on option.

🛡

Self-excited, PMG option

Excitation system self-excited as standard with PMG available for non-linear loads.

📦

Open, silent or container

Every model in open and silent-canopy builds; 1250 kVA and above containerized.

Open set

Open-frame sets

Skid-mounted sets with vibration isolators, industrial muffler and 50 degree radiator, ready for plant rooms and shelters.

Silent canopy

Silent and containerized sets

Weatherproof sound-attenuated canopies, moving to 20 and 40 ft containers at 1250 kVA and above.

The range · 50 Hz

Cummins 50 Hz, three phase

ModelPrime kW / kVAStandby kW / kVAEngineStamfordMecc AlteFOGENOpen set L×W×H mmkg (open)Silent L×W×H mmkg (silent)
FGC-3022 / 27.524.2 / 30.254B3.9-G1PI144FECP28 VL4AWHI84F1750×800×13507502280×950×15101100
FGC-3022 / 27.524.2 / 30.254B3.9-G2PI144FECP28 VL4AWHI84F1750×800×13507502280×950×15101100
FGC-4634 / 42.537.4 / 46.754BT3.9-G1PI144KECP32 3S4BWHI224C1750×800×13508002280×950×15101150
FGC-4634 / 42.537.4 / 46.754BT3.9-G2PI144KECP32 3S4BWHI224C1750×800×13508002280×950×15101150
FGC-5540 / 5044 / 554BTA3.9-G2UCI224DECP32 1M4BWHI224D1850×800×13508002280×950×15101150
FGC-6648 / 6052.8 / 664BTA3.9-G2UCI224EECP32 2M4BWHI224E1850×800×13508002280×950×15101150
FGC-8260 / 7566 / 82.54BTA3.9-G11UCI224FECP32 3L4BWHI224F1850×800×13508002280×950×15101150
FGC-11080 / 10088 / 1106BT5.9-G2UCI274CECP34 2S4AWHI274C2200×880×153010503000×1050×17401800
FGC-12090 / 112.599 / 123.756BTA5.9-G2UCI274DECP34 1L4AWHI274D2200×880×153010503000×1050×17401800
FGC-150112 / 140120 / 1506BTAA5.9-G2UCI274EECP34 2L4AWHI274E2350×880×153011003000×1050×17401850
FGC-170124 / 155136 / 1706BTAA5.9-G12UCI274FECP34 3L4AWHI274F2350×880×153011503000×1050×17401900
FGC-200145 / 180160 / 2006CTA8.3-G2UCI274GECO38 1S4AWHI274G2400×1000×171013803200×1200×19502800
FGC-225160 / 200176 / 2206CTAA8.3-G2UCI274HECO38 2S4AWHI274H2500×1000×171014803200×1200×19502900
FGC-275200 / 250220 / 2756LTAA8.9-G2UCDI274KECO38 1L4AWHI274K2500×1000×171014803200×1200×19502900
FGC-275200 / 250220 / 275NTA855-GAUCDI274KECO38 1L4AWHI274K3050×1150×200030004200×1500×22504500
FGC-312220 / 275250 / 312.5NTA855-G1AHCI444DECO38 2L4AWHI4D3050×1150×200032004200×1500×22504500
FGC-350250 / 312.5280 / 350NTA855-G1BHCI444ESECO38 3L4AWHI4ES3050×1150×200032004200×1500×22504500
FGC-375275 / 343.75300 / 375NTA855-G2AHCI444EECO38 3L4AWHI4FS3050×1150×200032004200×1500×22504500
FGC-412300 / 375330 / 412.5NTAA855-G7HCI444FSECO40 1S4AWHI4F3300×1150×200034004200×1500×22504700
FGC-450330 / 413360 / 450NTAA855-G7AHCI444FECO40 2S4AWHI5C3300×1150×200034004200×1500×22504700
FGC-500360 / 450400 / 500KTA19-G3HCI544CECO40 2S4AWHI5C3200×1400×220035004300×1600×22504800
FGC-562400 / 500450 / 562.5KTA19-G3AHCI544CECO40 1L4AWHI5D3200×1400×220035004300×1600×22504800
FGC-630420 / 525505 / 631.25KTAA19-G5HCI544DECO40 1.5L4AWHI5ES3430×1520×220036004500×1700×22505100
FGC-688454 / 567.5550 / 687.5KTAA19-G6AHCI544FSECO40 2L4AWHI5FS3430×1520×220036004500×1700×22505100
FGC-825600 / 750660 / 825KTA38-G2LVI634BECO40 VL4AWHI6B4500×1800×220075005800×2000×225010000
FGC-888640 / 800710 / 887.5KTA38-G2BLVI634CECO43 1S4AWHI6C4500×1800×220075005800×2000×225010000
FGC-1000728 / 910800 / 1000KTA38-G2ALV634DECO43 2S4AWHI6D4500×1800×220075005800×2000×225010000
FGC-1100800 / 1000800 / 1100KTA38-G5LV634EECO43 1M4AWHI6E4500×1800×220075005800×2000×225010000
FGC-1250910 / 1137.51000 / 1250KTA38-G9LVI634GECO43 2L4AWHI6G4500×1800×2200750020 ft container10000
FGC-13751000 / 12501100 / 1375KTA50-G3LV634GECO43 2L4AWHI6G4500×1800×2200750040 ft container10000
FGC-16251100 / 13751320 / 1650KTA50-G8PI734BECO43 VL4AWHI7B4900×2100×2530860040 ft container13800
FGC-16251180 / 14751320 / 1650KTA50-GS8PI734CECO46 1S4AWHI7C4900×2100×2530860040 ft container14000
The range · 60 Hz

Cummins 60 Hz, three phase

ModelPrime kW / kVAStandby kW / kVAEngineStamfordMecc AlteFOGENOpen set L×W×H mmkg (open)Silent L×W×H mmkg (silent)
FGC-33G124 / 3026.4 / 334B3.9-G1PI144EECP28 2L4AWHI184F1750×800×13507502280×950×15101100
FGC-33G224 / 3026.4 / 334B3.9-G2PI144EECP28 2L4AWHI184F1750×800×13507502280×950×15101100
FGC-50G136 / 4540 / 504BT3.9-G1PI144JECP32 3S4BWHI184H1750×800×13508002280×950×15101150
FGC-50G236 / 4540 / 504BT3.9-G2PI144JECP32 3S4BWHI184H1750×800×13508002280×950×15101150
FGC-6043 / 5448 / 604BTA3.9-G2UCI224DECP32 1M4BWHI224D1850×800×13508002280×950×15101150
FGC-7554 / 6860 / 754BTA3.9-G2UCI224EECP32 2M4BWHI224E1850×800×13508002280×950×15101150
FGC-9667 / 8477 / 964BTA3.9-G11UCI224FECP32 3L4BWHI224F1850×800×13508002280×950×15101150
FGC-11080 / 9988 / 1106BT5.9-G2UCI224GECP34 1S4AWHI274C2200×880×153010503000×1050×17401800
FGC-138100 / 125110 / 1386BTA5.9-G2UCI274CECP34 2S4AWHI274D2200×880×153010503000×1050×17401800
FGC-156112 / 140125 / 1566BTAA5.9-G2UCI274DECP34 1L4AWHI274ES2350×880×153011003000×1050×17401850
FGC-180130 / 162144 / 1806BTAA5.9-G12UCI274EECP34 1L4AWHI274E2350×880×153011503000×1050×17401900
FGC-209150 / 188167 / 2096CTA8.3-G2UCI274FECO34 3L4AWHI274F2400×1000×171013803200×1200×19502800
FGC-230166 / 207184 / 2306CTAA8.3-G2UCI274GECO38 1S4AWHI274G2400×1000×171013803200×1200×19502800
FGC-285205 / 257228 / 2856LTAA8.9-G2UCD274JECO38 3S4AWHI274J2500×1000×171014803200×1200×19502900
FGC-314226 / 283251 / 3146LTAA8.9-G3UCD274JECO38 1L4AWHI274K2500×1000×171014803200×1200×19502900
FGC-350252 / 315280 / 350NTA855-G1UCD274KECO38 2L4AWHI4D2500×1000×171014803200×1200×19502900
FGC-400288 / 360320 / 400NTA855-G1BHCI444DECO38 2L4AWHI4E3050×1150×200030004200×1500×22504500
FGC-438315 / 394350 / 438NTA855-G3HCI444ESECO38 3L4AWHI4FS3050×1150×200032004200×1500×22504500
FGC-500360 / 450400 / 500KTA19-G2HCI444FSECO40 1S4AWHI4F3050×1150×200032004200×1500×22504500
FGC-575414 / 518460 / 575KTA19-G3HCI544CECO40 2S4AWHI5C3050×1150×200032004200×1500×22504500
FGC-625450 / 563500 / 625KTA19-G3AHCI544CECO40 3S4AWHI5D3300×1150×200034004200×1500×22504700
FGC-690470 / 587550 / 687KTAA19-G5HCI544CECO40 3S4AWHI5D3300×1150×200034004200×1500×22504700
FGC-750600 / 750KTAA19-G6AHCI544EECO40 1.5L4AWHI5E3200×1400×220035005800×2000×22504800
FGC-850620 / 775680 / 850KTA38-GHCI544F-SECO40 2L4AWHI5FS3200×1400×220035005800×2000×22504800
FGC1000728 / 910800 / 1000KTA38-G2HCI634GECO40 VL4AWHI6C3430×1520×220036005800×2000×22505100
FGC-1100800 / 1000880 / 1100KTA38-G2AHCI634HECO43 2S4AWHI6D3430×1520×220036005800×2000×22505100
FGC-1250900 / 11251000 / 1250KTA38-G4LV634EECO43 2S4AWHI6E4500×1800×220075005800×2000×225010000
FGC-13751100 / 1375KTA38-G9HCI634JECO43 1M4AWHI6F4500×1800×2200750020 ft container10000
FGC-15751100 / 13751260 / 1575KTA50-G3HCI634KECO43 2M4AWHI6G4500×1800×2200750040 ft container10000
FGC-18751260 / 15751500 / 1875KTA50-G9PI734BECO43 VL4AWHI7B4500×1800×2200750040 ft container10000

All ratings follow ISO 8528 and ISO 3046: prime power allows 10% overload for one hour in every twelve; standby power covers up to 500 hours per year with no overload. Refer to the model datasheet for final ratings. Available voltages (50 Hz): 380/220 V, 400/230 V, 415/240 V, 440/254 V. Available voltages (60 Hz): 127/220 V, 132/230 V, 220/380 V, 254/440 V, 266/460 V, 277/488 V. Controller: DeepSea DSE6020 across the range.

Inside the set

Engineered around the Cummins engine

  • Cummins engine · DCEC, CCEC and Cummins USA built, from 4B3.9 to KTA50 platforms.
  • Vibration isolators · Fitted between the engine, alternator and base frame for smooth running.
  • Lockable battery isolator switch · Safe isolation for service, with complete protection functions and safety labels.
  • Circuit breaker · CHINT fitted as standard; ABB and LS breakers on option.
  • Base fuel tank · At least 8 hours of running; standard below 500 kVA, option above.
  • Industrial muffler and 50° radiator · Quiet exhaust with cooling margin for hot climates.
  • Steel base frame · Top lifting points and forklift holes, with fuel-tank drainage.
In the field

Cummins sets as delivered

Silent canopy build

Sound-attenuated enclosure with service doors and cooling louvres.

Inside the canopy

Engine, alternator and controller access through wide side doors.

Applications

Where Cummins sets are deployed

Telecom sites
Data centers
Hospitals & buildings
Industry & oil field

Scope your Cummins generator set

Share your load, voltage and site conditions. Our engineers confirm the right Cummins model, build format and options with a formal quotation.