The whole hall, engineered as one
Power train, cooling chain, white space and supervision: FIBER OCEAN designs them together, from the 10 kVA server room to the liquid-cooled AI hall, so every kilowatt in is a kilowatt computed, cooled and accounted for.
Four chains, one design
A data center is four chains that must agree with each other. We engineer all four from our own lines, sized together against your load profile.
Power it
Tower, modular and rack UPS with lithium or VRLA autonomy, and standby gensets up to 3,300 kVA at 11 kV behind them.
Cool it
The full escalation: room CRAC to 177 kW, in-row close coupling, rack-mount units, then liquid AIDC containers and immersion.
House it
Cabinets from 6 to 47U with smart PDUs, aisle containment, or the whole room as a modular, micro or prefab build.
Run it
FO-MC4.0 supervises power, environment, video, access and U-position from one collector, no server room required for the monitor itself.
Anatomy of a FIBER OCEAN hall
Eight layers, one supplier, one supervision plane. Every numbered element is a FIBER OCEAN line, sized together.
| Layer | What we deploy | Product line |
|---|---|---|
| 1. Uninterruptible power | Tower UPS from 10 to 500 kVA, modular UPS up to 1600 kVA and 1–20 kVA rack UPS | UPS Systems |
| 2. Backup energy | 48 V lithium and VRLA strings behind the UPS bus | Batteries |
| 3. Standby generation | Data-center gensets up to high-voltage sets of 3,300 kVA at 11 kV | Diesel Generators |
| 4. Cooling | Room CRAC to 177 kW, in-row, rack-mount, outdoor cabinet, liquid AIDC and immersion | Cooling Systems |
| 5. Racks & rack power | Server and network cabinets from 6 to 47U with smart PDUs metering every outlet | IT Racks & Smart PDU |
| 6. Supervision | FO-MC4.0: up to 12,000 measurement points, access control and U-position on one collector | DCIM & Monitoring |
| 7. Structured fiber | MPO/MTP trunks to 100G, patch panels and ODF for the meet-me space | Fiber Optics and Accessories |
| 8. The building block | Modular, containment, micro and prefab data center builds when the room itself is the product | Modular Data Centers |
From one rack to an AI hall
The same eight layers, composed differently at every scale.
Micro data centers
A rack UPS from 1 to 20 kVA, rack-mount cooling, a smart PDU and FO-MC4.0 in one integrated cabinet: the computer room, condensed.
Modular & containment
Contained aisles with in-row cooling, modular UPS growing with the load, and the whole room delivered as an engineered block.
Prefab & container
Factory-built capacity dropped on site: power, cooling and white space commissioned as one unit, HV standby behind it.
Liquid-cooled AI halls
AIDC container modules in 20FT and 40ft builds up to 100KW, immersion cabinets and PUE approaching 1.1 for dense GPU loads.
Engineered to agree with itself
The details that make one hall behave like one system instead of five procurements.
A cooling path, not a unit
Start on room CRAC, add in-row close coupling as density rises, land on liquid AIDC or immersion: one vendor across the whole escalation.
Every outlet accounted
Smart PDUs meter and switch per outlet, cascade up to 32 units from one host, and speak SNMP or Modbus to the same supervision plane.
Assets that report themselves
U-position strips on 42, 47 and 52U racks log every move; face capture and access control guard the hall door on the same collector.
Growth without forklift
Modular UPS scales in steps, containment adds aisles, container modules add halls: capacity follows the load curve, not the other way.
A monitor that cannot crash the room
The FO-MC4.0 collector is fanless ARM Linux with dual watchdog and over 1.2 million hours MTBF, and needs no server, OS or database.
Fiber ready for 100G
MPO/MTP trunks, cassettes and modules from 8 to 24 fibers wire the hall for 10G to 100G without re-pulling.
A Tuesday afternoon, fully supervised
Illustrative feed. Every event type is documented FO-MC4.0 or smart-PDU capability: up to 12,000 measurement points, one integrated collector with no server, OS or database, and over 1.2 million hours MTBF.
Bring us your load profile
Rack count, kW per rack, growth curve and site constraints. Our engineers return a sized power and cooling chain, a supervision plan and a quotation.