Data Centers

The whole hall, engineered as one

Power train, cooling chain, white space and supervision: FIBER OCEAN designs them together, from the 10 kVA server room to the liquid-cooled AI hall, so every kilowatt in is a kilowatt computed, cooled and accounted for.

The solution

Four chains, one design

A data center is four chains that must agree with each other. We engineer all four from our own lines, sized together against your load profile.

Power it

Tower, modular and rack UPS with lithium or VRLA autonomy, and standby gensets up to 3,300 kVA at 11 kV behind them.

Cool it

The full escalation: room CRAC to 177 kW, in-row close coupling, rack-mount units, then liquid AIDC containers and immersion.

🗄

House it

Cabinets from 6 to 47U with smart PDUs, aisle containment, or the whole room as a modular, micro or prefab build.

🗺

Run it

FO-MC4.0 supervises power, environment, video, access and U-position from one collector, no server room required for the monitor itself.

10–1600 kVA
Tower & modular UPS range
177 kW
Largest room CRAC
≈1.1
PUE with immersion cooling
3,300 kVA
HV standby at 11 kV
12,000
DCIM measurement points
100G
MPO/MTP trunk systems
The hall as one system

Anatomy of a FIBER OCEAN hall

Eight layers, one supplier, one supervision plane. Every numbered element is a FIBER OCEAN line, sized together.

Anatomy of a FIBER OCEAN data hall: UPS and battery power zone, contained rack aisle with in-row cooling and overhead fiber trunks, room CRAC, monitoring wall with access control and standby generation outside, with numbered callouts matching the table below
LayerWhat we deployProduct line
1. Uninterruptible powerTower UPS from 10 to 500 kVA, modular UPS up to 1600 kVA and 1–20 kVA rack UPSUPS Systems
2. Backup energy48 V lithium and VRLA strings behind the UPS busBatteries
3. Standby generationData-center gensets up to high-voltage sets of 3,300 kVA at 11 kVDiesel Generators
4. CoolingRoom CRAC to 177 kW, in-row, rack-mount, outdoor cabinet, liquid AIDC and immersionCooling Systems
5. Racks & rack powerServer and network cabinets from 6 to 47U with smart PDUs metering every outletIT Racks & Smart PDU
6. SupervisionFO-MC4.0: up to 12,000 measurement points, access control and U-position on one collectorDCIM & Monitoring
7. Structured fiberMPO/MTP trunks to 100G, patch panels and ODF for the meet-me spaceFiber Optics and Accessories
8. The building blockModular, containment, micro and prefab data center builds when the room itself is the productModular Data Centers
Build scenarios

From one rack to an AI hall

The same eight layers, composed differently at every scale.

Server room & edge

Micro data centers

A rack UPS from 1 to 20 kVA, rack-mount cooling, a smart PDU and FO-MC4.0 in one integrated cabinet: the computer room, condensed.

Room scale

Modular & containment

Contained aisles with in-row cooling, modular UPS growing with the load, and the whole room delivered as an engineered block.

Site scale

Prefab & container

Factory-built capacity dropped on site: power, cooling and white space commissioned as one unit, HV standby behind it.

AI & HPC

Liquid-cooled AI halls

AIDC container modules in 20FT and 40ft builds up to 100KW, immersion cabinets and PUE approaching 1.1 for dense GPU loads.

Why it holds together

Engineered to agree with itself

The details that make one hall behave like one system instead of five procurements.

A cooling path, not a unit

Start on room CRAC, add in-row close coupling as density rises, land on liquid AIDC or immersion: one vendor across the whole escalation.

🔌

Every outlet accounted

Smart PDUs meter and switch per outlet, cascade up to 32 units from one host, and speak SNMP or Modbus to the same supervision plane.

📊

Assets that report themselves

U-position strips on 42, 47 and 52U racks log every move; face capture and access control guard the hall door on the same collector.

Growth without forklift

Modular UPS scales in steps, containment adds aisles, container modules add halls: capacity follows the load curve, not the other way.

🛡

A monitor that cannot crash the room

The FO-MC4.0 collector is fanless ARM Linux with dual watchdog and over 1.2 million hours MTBF, and needs no server, OS or database.

🔗

Fiber ready for 100G

MPO/MTP trunks, cassettes and modules from 8 to 24 fibers wire the hall for 10G to 100G without re-pulling.

Inside the hall

A Tuesday afternoon, fully supervised

Illustrative feed. Every event type is documented FO-MC4.0 or smart-PDU capability: up to 12,000 measurement points, one integrated collector with no server, OS or database, and over 1.2 million hours MTBF.

Bring us your load profile

Rack count, kW per rack, growth curve and site constraints. Our engineers return a sized power and cooling chain, a supervision plan and a quotation.

Request a Solution Proposal