Micro Data Centers

A complete data center, the size of a cabinet

The AquaCore I-Rack puts power, cooling, racks, fire suppression and monitoring inside one sealed enclosure. It stands in the branch, the clinic, the office corner, anywhere IT lives without a room of its own, and behaves like the hall it replaced.

The solution

Small footprint, full discipline

A micro data center is not a small compromise; it is a whole data center’s duties honored at cabinet scale.

🗄

Arrives whole

UPS, cooling, racks, distribution, fire suppression and monitoring integrated and tested in one enclosure before delivery.

Runs like a hall

2N power architecture and N+X cooling redundancy: the disciplines of the big room, kept at cabinet scale.

🛡

Protects itself

Gas suppression, emergency ventilation, anti-condensation control and Class C lightning protection, all inside the box.

🗺

Never alone

The door touchscreen runs the cabinet; APP, web and the operating center watch it from wherever you are.

3–30 kVA
Rack UPS range, 2N
1–5
IT cabinets per build
≤1.4
PUE at cabinet scale
±0.5 °C
Cooling accuracy
≤49 dB
Quiet enough for the office
24/7
NOC & customer support
Inside the cabinet

Anatomy of a FIBER OCEAN micro data center

Seven layers behind one door. Every numbered element is a FIBER OCEAN line, integrated before the cabinet ships.

Anatomy of a FIBER OCEAN micro data center: open I-Rack smart cabinet showing the monitoring unit, rack-mount cooling, rack UPS, battery units, smart PDU strips and the gas fire-suppression unit, with the door-mounted touchscreen, beside a second closed cabinet, with numbered callouts matching the table below
LayerWhat we deployProduct line
1. The I-Rack cabinetIP5X fully enclosed with closed cold / hot isolation, from the single-cabinet EC20 to the five-cabinet ER05 rowAquaCore Micro DC Series
2. Rack UPS3–30 kVA rack-mountable in a 2N architecture, with ultra-wide voltage input and phase-sequence detectionUPS Systems
3. Battery ride-through15 to 120 minutes, configurable on demand to what the site’s risk assessment asks forBatteries
4. Close-coupled cooling3.5 up to 2×12.5 kW holding ±0.5 °C, inverter compressors and dual EC fans in N+X, emergency ventilation to 5 kWRack-Mount Cooling
5. White spaceUp to 30U in the integrated cabinet; row builds add up to four standard 42U IT cabinets with smart PDUsIT Racks & Smart PDU
6. Fire built inOptional heptafluoropropane 1U gas suppression engineered into the enclosure, with Class C lightning protectionAquaCore Data Centers
7. The touchscreen brainA 10-inch HMI watches UPS, distribution, cooling, leakage, temperature-humidity, smoke and door, with 12-month energy trendsDCIM & Monitoring
Edge scenarios

Wherever IT lives without a room

The same cabinet, configured for the place it stands.

Branch & clinic

The closet that grew up

One integrated cabinet replaces the shelf of adapters behind the door: sealed, cooled, backed up and monitored like the head office hall.

Open office

The cabinet beside the desks

At or under 49 dB with closed cold / hot isolation, the data center stands in the workspace without anyone asking it to leave.

Growing site

The row that grows

Start with a single cabinet; row builds carry up to four additional 42U IT cabinets on the same cooling and power spine.

Distributed estate

The fleet of small rooms

Hundreds of branches, one design, and every cabinet’s touchscreen reporting to the same operating center.

Why the I-Rack wins

Hall-grade habits, cabinet-size bill

The details that make a micro data center an infrastructure decision, not a furniture purchase.

Half a degree of discipline

Close-coupled cooling holds ±0.5 °C with inverter compressors and dual EC fans in N+X, and anti-condensation control at low load.

🔥

Fire answered in one U

The optional heptafluoropropane system lives inside the rack, engineered with the airflow, sized for the enclosure it protects.

Ride-through by policy

Battery backup from 15 to 120 minutes, configured to the site’s risk assessment instead of whatever fit the shelf.

📊

A year of memory

The HMI keeps 12-month energy trends on the door, so the branch’s power story is a graph, not a guess.

Certified, not improvised

ISO 9001 and 14001, CE, CCC, CQC and CRAA behind the product family, from a platform sold at every scale above it.

🗺

Watched like the big room

Leakage, temperature-humidity, smoke and door events stream from every cabinet to the same operating center as the halls.

Inside the fleet

One day across the small rooms

Illustrative feed. Every event type is documented I-Rack monitoring capability (UPS, distribution, cooling, leakage, temperature-humidity, smoke and door, with 12-month energy trends) reported through APP, web and the operating center, supported 24/7.

Bring us your edge load

Sites, kW per site, ride-through targets and where the cabinet will stand. Our engineers return a model selection, a fleet supervision plan and a quotation.

Request a Solution Proposal