A complete data center, the size of a cabinet
The AquaCore I-Rack puts power, cooling, racks, fire suppression and monitoring inside one sealed enclosure. It stands in the branch, the clinic, the office corner, anywhere IT lives without a room of its own, and behaves like the hall it replaced.
Small footprint, full discipline
A micro data center is not a small compromise; it is a whole data center’s duties honored at cabinet scale.
Arrives whole
UPS, cooling, racks, distribution, fire suppression and monitoring integrated and tested in one enclosure before delivery.
Runs like a hall
2N power architecture and N+X cooling redundancy: the disciplines of the big room, kept at cabinet scale.
Protects itself
Gas suppression, emergency ventilation, anti-condensation control and Class C lightning protection, all inside the box.
Never alone
The door touchscreen runs the cabinet; APP, web and the operating center watch it from wherever you are.
Anatomy of a FIBER OCEAN micro data center
Seven layers behind one door. Every numbered element is a FIBER OCEAN line, integrated before the cabinet ships.
| Layer | What we deploy | Product line |
|---|---|---|
| 1. The I-Rack cabinet | IP5X fully enclosed with closed cold / hot isolation, from the single-cabinet EC20 to the five-cabinet ER05 row | AquaCore Micro DC Series |
| 2. Rack UPS | 3–30 kVA rack-mountable in a 2N architecture, with ultra-wide voltage input and phase-sequence detection | UPS Systems |
| 3. Battery ride-through | 15 to 120 minutes, configurable on demand to what the site’s risk assessment asks for | Batteries |
| 4. Close-coupled cooling | 3.5 up to 2×12.5 kW holding ±0.5 °C, inverter compressors and dual EC fans in N+X, emergency ventilation to 5 kW | Rack-Mount Cooling |
| 5. White space | Up to 30U in the integrated cabinet; row builds add up to four standard 42U IT cabinets with smart PDUs | IT Racks & Smart PDU |
| 6. Fire built in | Optional heptafluoropropane 1U gas suppression engineered into the enclosure, with Class C lightning protection | AquaCore Data Centers |
| 7. The touchscreen brain | A 10-inch HMI watches UPS, distribution, cooling, leakage, temperature-humidity, smoke and door, with 12-month energy trends | DCIM & Monitoring |
Wherever IT lives without a room
The same cabinet, configured for the place it stands.
The closet that grew up
One integrated cabinet replaces the shelf of adapters behind the door: sealed, cooled, backed up and monitored like the head office hall.
The cabinet beside the desks
At or under 49 dB with closed cold / hot isolation, the data center stands in the workspace without anyone asking it to leave.
The row that grows
Start with a single cabinet; row builds carry up to four additional 42U IT cabinets on the same cooling and power spine.
The fleet of small rooms
Hundreds of branches, one design, and every cabinet’s touchscreen reporting to the same operating center.
Hall-grade habits, cabinet-size bill
The details that make a micro data center an infrastructure decision, not a furniture purchase.
Half a degree of discipline
Close-coupled cooling holds ±0.5 °C with inverter compressors and dual EC fans in N+X, and anti-condensation control at low load.
Fire answered in one U
The optional heptafluoropropane system lives inside the rack, engineered with the airflow, sized for the enclosure it protects.
Ride-through by policy
Battery backup from 15 to 120 minutes, configured to the site’s risk assessment instead of whatever fit the shelf.
A year of memory
The HMI keeps 12-month energy trends on the door, so the branch’s power story is a graph, not a guess.
Certified, not improvised
ISO 9001 and 14001, CE, CCC, CQC and CRAA behind the product family, from a platform sold at every scale above it.
Watched like the big room
Leakage, temperature-humidity, smoke and door events stream from every cabinet to the same operating center as the halls.
One day across the small rooms
Illustrative feed. Every event type is documented I-Rack monitoring capability (UPS, distribution, cooling, leakage, temperature-humidity, smoke and door, with 12-month energy trends) reported through APP, web and the operating center, supported 24/7.
Bring us your edge load
Sites, kW per site, ride-through targets and where the cabinet will stand. Our engineers return a model selection, a fleet supervision plan and a quotation.