Cooling Systems: from the rack to the room to the tank
Seven cooling paths cover every heat load in digital infrastructure: room precision CRAC to 177 kW, in-row, rack-mount and fan wall units, 600 to 3000 W outdoor DC cabinet coolers, and liquid and immersion cooling with CDUs to 4×400 kW and PUE approaching 1.1.
One thermal partner for every layer of the site
FIBER OCEAN cooling spans air, water and liquid: precision room air conditioning, close-coupled in-row and in-rack units, sealed DC-powered coolers for outdoor cabinets, and single- or two-phase immersion platforms for AI-class density. Every product family carries open monitoring interfaces so the whole thermal estate reports into one DCIM.
0.6 to 400 kW
From 600 W cabinet coolers to 177 kW room CRAC units and 400 kW coolant distribution units.
Air, water & liquid
DX air-cooled, water-cooled, chilled-water, free-cooling and immersion technologies from one supplier.
Efficiency first
EC fans, inverter compressors and immersion PUE approaching 1.1 cut energy across the estate.
Open monitoring
RS485, Modbus, SNMP, BACnet and Modbus TCP across the range for DCIM and BMS integration.
Cooling Systems line-up
Room Precision Cooling
Datacool and Cyber Master precision air conditioners: DX, water-cooled and chilled-water from 7.5 to 177 kW with ±1 °C control.
View rangeIn-Row Cooling
DataRow close-coupled 42U row units, DX 7.5 to 90.5 kW and chilled-water to 107.6 kW, modulating 20 to 100%.
View rangeRack-Mount Cooling
Data-R packaged and split units, 3.5 to 12.5 kW in 6U to 12U, for micro and mini modular data centers.
View rangeFan Wall Units
High-airflow fan wall modules for modular and containment halls, part of the AquaCore technology platform.
ExploreOutdoor Cabinet Air Conditioners
FO-DC monoblock coolers, 600 to 3000 W on −48 VDC, IP55-sealed for off-grid and hybrid-powered cabinets.
View rangeFluid-Immersion Cooling
Integrated 10 kW cabinets, ATH immersion TANKs from 13U to 54U and CDUs from 5 to 400 kW, single- or two-phase, PUE down to about 1.1.
View rangeLiquid Cooling AIDC Solutions
Containerized 20 ft and 40 ft liquid-cooled data centers: cold plate and immersion, CDUs to 4 × 400 kW, PUE as low as 1.38.
View rangeNot sure which cooling category fits your site?
Send your heat load, room or cabinet dimensions and site conditions. Our engineers reply with a recommended configuration, capacity sizing and budgetary quotation.
Cooling for every application and solution
Cooling Systems datasheets
Detailed specifications, formats and options for the Cyber Master precision cooling range. Our team shares the current datasheet pack on request.
Scope your Cooling Systems
Share your load, site and redundancy requirements. Our engineers respond with a tailored configuration.