FPT-powered generators: 31 to 550 kVA
FOGEN generator sets on Italian-made FPT (Iveco) engines with DeepSea DSE7320 controllers with AMF, from the F32 to the CURSOR 13 platform.
What this range delivers
Twenty-eight build variants across 50 and 60 Hz, from 25 to 400 kW prime, in open and silent formats.
25 to 400 kW prime
F32, N45, N67, R87, C13 and CR13 FPT platforms at 50 and 60 Hz.
DeepSea DSE7320
AMF function standard across the whole FPT range.
Made in Italy
FPT Industrial powertrains with European build quality.
Open or silent
Every model in open-frame and sound-attenuated builds.
Open-frame sets
Compact white-alternator sets with clean service access.
FPT powertrain
Iveco-built blocks with efficient combustion and long service intervals.
FPT 50 Hz, three phase
| Model | Prime kW / kVA | Standby kW / kVA | Engine | Stamford | Mecc Alte | FOGEN | Open set L×W×H mm | kg (open) | Silent L×W×H mm | kg (silent) |
|---|---|---|---|---|---|---|---|---|---|---|
| FGFa-35 | 25 / 31 | 28 / 35 | F32 AM1A | PI144G | ECP28 VL4A | WHI184G | 1750×800×1350 | 750 | 2280×950×1510 | 1100 |
| FGF-44 | 32 / 40 | 35 / 44 | F32 SM1A | PI144J | ECP32 3S4B | WHI224C | 1750×800×1350 | 800 | 2280×950×1510 | 1150 |
| FGF-52 | 40 / 50 | 42 / 52 | F32TM1A | UCI224D | ECP32 1M4B | WHI224D | 1850×800×1350 | 800 | 2280×950×1510 | 1150 |
| FGF-66 | 48 / 60 | 53 / 66 | N45 SM 1A | UCI224E | ECP32 2M4B | WHI224F | 1850×800×1350 | 800 | 2280×950×1510 | 1150 |
| FGF-84 | 64 / 80 | 67 / 84 | N45 SM 3A | UCI224G | ECP32 4L4B | WHI224G | 1850×800×1350 | 800 | 2280×950×1510 | 1150 |
| FGF-110 | 80 / 100 | 88 / 110 | N45 TM2A | UCI274C | ECP34 2S4A | WHI274C | 2200×880×1530 | 1050 | 3000×1050×1740 | 1800 |
| FGF-143 | 105 / 131 | 114 / 143 | N67 TM2A | UCI274E | ECP34 1L4A | WHI274E | 2200×880×1530 | 1050 | 3000×1050×1740 | 1800 |
| FGF-165 | 120 / 150 | 132 / 165 | N67 TM3A | UCI274F | ECP34 2L4A | WHI274F | 2350×880×1530 | 1100 | 3000×1050×1740 | 1850 |
| FGF-220 | 160 / 200 | 176 / 220 | N67 TE2A | UCI274H | ECO38 2S4A | WHI274H | 2500×1000×1710 | 1480 | 3200×1200×1950 | 2900 |
| FGF-275 | 200 / 250 | 220 / 275 | R87TE3 | UCDI274K | ECO38 1L4A | WHI274K | 3050×1150×2000 | 3000 | 4200×1500×2250 | 4500 |
| FGF-330 | 240 / 300 | 264 / 330 | R87TE4 | HCI444D | ECO38 2L4A | WHI 4D | 3050×1150×2000 | 3200 | 4200×1500×2250 | 4500 |
| FGF-380 | 280 / 350 | 224 / 280 | C13 TE 2A | HCI444E | ECO38 3L4A | WHI 4FS | 3050×1150×2000 | 3200 | 4200×1500×2250 | 4500 |
| FGF-440 | 320 / 400 | 352 / 440 | C13 TE 3A | HCI444F | ECO40 1S4A | WHI4G | 3300×1150×2000 | 3400 | 4200×1500×2250 | 4700 |
| FGF-500 | 360 / 450 | 400 / 500 | CR13 TE6 | HCI544C | ECO40 2S4A | WHI5C | 3300×1150×2000 | 3400 | 4200×1500×2250 | 4700 |
| FGF-550 | 400 / 500 | 440 / 550 | CR13 TE7 | HCI544C | ECO40 3S4A | WHI5D | 3200×1400×2200 | 3500 | 4300×1600×2250 | 4800 |
FPT 60 Hz, three phase
| Model | Prime kW / kVA | Standby kW / kVA | Engine | Stamford | Mecc Alte | FOGEN | Open set L×W×H mm | kg (open) | Silent L×W×H mm | kg (silent) |
|---|---|---|---|---|---|---|---|---|---|---|
| FGF-50 | 36 / 36 | 40 / 50 | F32SM1X.A008 | PI144J | ECP32 3S4B | WHI184H | 1750×800×1350 | 800 | 2280×950×1510 | 1150 |
| FGF-63 | 45.6 / 45.6 | 50.4 / 63 | F32TM1X.A008 | UCI224C | ECP32 1M4B | WHI224D | 1850×800×1350 | 800 | 2280×950×1510 | 1150 |
| FGF-63 | 45.6 / 45.6 | 50.4 / 63 | NEF45SM1X.A008 | UCI224C | ECP32 1M4B | WHI224D | 1850×800×1350 | 800 | 2280×950×1510 | 1150 |
| FGF-75 | 54.4 / 54.4 | 60 / 75 | NEF45SM2X.A008 | UCI224E | ECP32 2M4B | WHI224E | 1850×800×1350 | 800 | 2280×950×1510 | 1150 |
| FGF-106 | 77.6 / 77.6 | 84.8 / 106 | NEF45TM2X.A008 | UCI224G | ECP32 4L4B | WHI224G | 1850×800×1350 | 800 | 2280×950×1510 | 1150 |
| FGF-156 | 113.6 / 113.6 | 124.8 / 156 | NEF67TM1X.A008 | UCI274D | ECP34 1L4A | WHI274D | 2200×880×1530 | 1050 | 3000×1050×1740 | 1800 |
| FGF-143 | 136 / 136 | 114.4 / 143 | NEF67TE1X.A008 | UCI274E | ECP34 2L4A | WHI274E | 2350×880×1530 | 1100 | 3000×1050×1740 | 1850 |
| FGF-165 | 159.2 / 159.2 | 132 / 165 | NEF67TE2X.A008 | UCI274F | ECO38 1S4A | WHI274G | 2500×1000×1710 | 1480 | 3200×1200×1950 | 2900 |
| FGF-220 | 227.2 / 227.2 | 176 / 220 | CURSOR87TE1D.A008 | UCDI274J | ECO38 3S4A | WHI274K | 3050×1150×2000 | 3000 | 4200×1500×2250 | 4500 |
| FGF-275 | 259.2 / 259.2 | 220 / 275 | CURSOR10TE1D.A008 | HCI444C | ECO38 2L4A | WHI4D | 3050×1150×2000 | 3200 | 4200×1500×2250 | 4500 |
| FGF-330 | 313.6 / 313.6 | 264 / 330 | CURSOR13TE3X.A008 | HCI444ES | ECO38 3L4A | WHI4ES | 3050×1150×2000 | 3200 | 4200×1500×2250 | 4500 |
| FGF-500 | 360 / 360 | 400 / 500 | CR13TE6W. S550 | HCI444FS | ECO40 1S4A | WHI4F | 3300×1150×2000 | 3400 | 4200×1500×2250 | 4700 |
| FGF-550 | 400 / 400 | 440 / 550 | CR13TE7W. S550 | HCI444F | ECO40 2S4A | WHI4G | 3300×1150×2000 | 3400 | 4200×1500×2250 | 4700 |
All ratings follow ISO 8528 and ISO 3046: prime power allows 10% overload for one hour in every twelve; standby power covers up to 500 hours per year with no overload. Refer to the model datasheet for final ratings. Available voltages (50 Hz): 380/220 V, 400/230 V, 415/240 V, 440/254 V. Available voltages (60 Hz): 127/220 V, 132/230 V, 220/380 V, 254/440 V, 266/460 V, 277/488 V. Controller: DeepSea DSE7320 across the range.
Engineered around the FPT engine
- FPT engine · Made in Italy, from the F32 to CURSOR 13 marine-derived blocks.
- Vibration isolators · Fitted between the engine, alternator and base frame for smooth running.
- Lockable battery isolator switch · Safe isolation for service, with complete protection functions and safety labels.
- Circuit breaker · CHINT fitted as standard; ABB and LS breakers on option.
- Base fuel tank · At least 8 hours of running; standard below 500 kVA, option above.
- Industrial muffler and 50° radiator · Quiet exhaust with cooling margin for hot climates.
- Steel base frame · Top lifting points and forklift holes, with fuel-tank drainage.
FPT powertrain details
Turbocharger and manifolds
FPT turbocharging with precision fuel delivery.
Fuel filtration
IVECO spin-on filters with water separation.
Where FPT sets are deployed
Scope your FPT generator set
Share your load, voltage and site conditions. Our engineers confirm the right FPT model, build format and options with a formal quotation.