Skip to content
Diesel Generators · FPT

FPT-powered generators: 31 to 550 kVA

FOGEN generator sets on Italian-made FPT (Iveco) engines with DeepSea DSE7320 controllers with AMF, from the F32 to the CURSOR 13 platform.

Overview

What this range delivers

Twenty-eight build variants across 50 and 60 Hz, from 25 to 400 kW prime, in open and silent formats.

25 to 400 kW prime

F32, N45, N67, R87, C13 and CR13 FPT platforms at 50 and 60 Hz.

DeepSea DSE7320

AMF function standard across the whole FPT range.

🛡

Made in Italy

FPT Industrial powertrains with European build quality.

📦

Open or silent

Every model in open-frame and sound-attenuated builds.

Open set

Open-frame sets

Compact white-alternator sets with clean service access.

Engine detail

FPT powertrain

Iveco-built blocks with efficient combustion and long service intervals.

The range · 50 Hz

FPT 50 Hz, three phase

ModelPrime kW / kVAStandby kW / kVAEngineStamfordMecc AlteFOGENOpen set L×W×H mmkg (open)Silent L×W×H mmkg (silent)
FGFa-3525 / 3128 / 35F32 AM1API144GECP28 VL4AWHI184G1750×800×13507502280×950×15101100
FGF-4432 / 4035 / 44F32 SM1API144JECP32 3S4BWHI224C1750×800×13508002280×950×15101150
FGF-5240 / 5042 / 52F32TM1AUCI224DECP32 1M4BWHI224D1850×800×13508002280×950×15101150
FGF-6648 / 6053 / 66N45 SM 1AUCI224EECP32 2M4BWHI224F1850×800×13508002280×950×15101150
FGF-8464 / 8067 / 84N45 SM 3AUCI224GECP32 4L4BWHI224G1850×800×13508002280×950×15101150
FGF-11080 / 10088 / 110N45 TM2AUCI274CECP34 2S4AWHI274C2200×880×153010503000×1050×17401800
FGF-143105 / 131114 / 143N67 TM2AUCI274EECP34 1L4AWHI274E2200×880×153010503000×1050×17401800
FGF-165120 / 150132 / 165N67 TM3AUCI274FECP34 2L4AWHI274F2350×880×153011003000×1050×17401850
FGF-220160 / 200176 / 220N67 TE2AUCI274HECO38 2S4AWHI274H2500×1000×171014803200×1200×19502900
FGF-275200 / 250220 / 275R87TE3UCDI274KECO38 1L4AWHI274K3050×1150×200030004200×1500×22504500
FGF-330240 / 300264 / 330R87TE4HCI444DECO38 2L4AWHI 4D3050×1150×200032004200×1500×22504500
FGF-380280 / 350224 / 280C13 TE 2AHCI444EECO38 3L4AWHI 4FS3050×1150×200032004200×1500×22504500
FGF-440320 / 400352 / 440C13 TE 3AHCI444FECO40 1S4AWHI4G3300×1150×200034004200×1500×22504700
FGF-500360 / 450400 / 500CR13 TE6HCI544CECO40 2S4AWHI5C3300×1150×200034004200×1500×22504700
FGF-550400 / 500440 / 550CR13 TE7HCI544CECO40 3S4AWHI5D3200×1400×220035004300×1600×22504800
The range · 60 Hz

FPT 60 Hz, three phase

ModelPrime kW / kVAStandby kW / kVAEngineStamfordMecc AlteFOGENOpen set L×W×H mmkg (open)Silent L×W×H mmkg (silent)
FGF-5036 / 3640 / 50F32SM1X.A008PI144JECP32 3S4BWHI184H1750×800×13508002280×950×15101150
FGF-6345.6 / 45.650.4 / 63F32TM1X.A008UCI224CECP32 1M4BWHI224D1850×800×13508002280×950×15101150
FGF-6345.6 / 45.650.4 / 63NEF45SM1X.A008UCI224CECP32 1M4BWHI224D1850×800×13508002280×950×15101150
FGF-7554.4 / 54.460 / 75NEF45SM2X.A008UCI224EECP32 2M4BWHI224E1850×800×13508002280×950×15101150
FGF-10677.6 / 77.684.8 / 106NEF45TM2X.A008UCI224GECP32 4L4BWHI224G1850×800×13508002280×950×15101150
FGF-156113.6 / 113.6124.8 / 156NEF67TM1X.A008UCI274DECP34 1L4AWHI274D2200×880×153010503000×1050×17401800
FGF-143136 / 136114.4 / 143NEF67TE1X.A008UCI274EECP34 2L4AWHI274E2350×880×153011003000×1050×17401850
FGF-165159.2 / 159.2132 / 165NEF67TE2X.A008UCI274FECO38 1S4AWHI274G2500×1000×171014803200×1200×19502900
FGF-220227.2 / 227.2176 / 220CURSOR87TE1D.A008UCDI274JECO38 3S4AWHI274K3050×1150×200030004200×1500×22504500
FGF-275259.2 / 259.2220 / 275CURSOR10TE1D.A008HCI444CECO38 2L4AWHI4D3050×1150×200032004200×1500×22504500
FGF-330313.6 / 313.6264 / 330CURSOR13TE3X.A008HCI444ESECO38 3L4AWHI4ES3050×1150×200032004200×1500×22504500
FGF-500360 / 360400 / 500CR13TE6W. S550HCI444FSECO40 1S4AWHI4F3300×1150×200034004200×1500×22504700
FGF-550400 / 400440 / 550CR13TE7W. S550HCI444FECO40 2S4AWHI4G3300×1150×200034004200×1500×22504700

All ratings follow ISO 8528 and ISO 3046: prime power allows 10% overload for one hour in every twelve; standby power covers up to 500 hours per year with no overload. Refer to the model datasheet for final ratings. Available voltages (50 Hz): 380/220 V, 400/230 V, 415/240 V, 440/254 V. Available voltages (60 Hz): 127/220 V, 132/230 V, 220/380 V, 254/440 V, 266/460 V, 277/488 V. Controller: DeepSea DSE7320 across the range.

Inside the set

Engineered around the FPT engine

  • FPT engine · Made in Italy, from the F32 to CURSOR 13 marine-derived blocks.
  • Vibration isolators · Fitted between the engine, alternator and base frame for smooth running.
  • Lockable battery isolator switch · Safe isolation for service, with complete protection functions and safety labels.
  • Circuit breaker · CHINT fitted as standard; ABB and LS breakers on option.
  • Base fuel tank · At least 8 hours of running; standard below 500 kVA, option above.
  • Industrial muffler and 50° radiator · Quiet exhaust with cooling margin for hot climates.
  • Steel base frame · Top lifting points and forklift holes, with fuel-tank drainage.
In the field

FPT powertrain details

Turbocharger and manifolds

FPT turbocharging with precision fuel delivery.

Fuel filtration

IVECO spin-on filters with water separation.

Applications

Where FPT sets are deployed

Telecom sites
Data centers
Hospitals & buildings
Industry & oil field

Scope your FPT generator set

Share your load, voltage and site conditions. Our engineers confirm the right FPT model, build format and options with a formal quotation.

Request a Quote