Infrastructure for care that never closes
Operating theatres, imaging suites and clinical IT run on the same physics as any critical load, with none of the tolerance. FIBER OCEAN engineers the hospital’s power, cooling, white space and supervision as one system, sized for the loads that cannot wait.
Four duties, one system
A hospital’s infrastructure owes four duties to the people inside it. We engineer all four from our own lines, so no seam between suppliers ever reaches a patient.
Never blink
Tower, modular and rack UPS with lithium or VRLA autonomy behind theatres, imaging and clinical IT, and standby gensets behind everything.
Hold the environment
Precision cooling that holds temperature to ±1 °C and humidity to ±5% in equipment rooms that run 24 hours a day, 365 days a year.
Guard the rooms
Access control and CCTV on server rooms, pharmacies and records, with leak, temperature-humidity and smoke sensing on the same collector.
Prove it happened
Auditable monitoring across power, environment and access: curves, alarms and reports the compliance office can actually use.
Anatomy of a FIBER OCEAN hospital campus
Eight layers, one supplier, one supervision plane. Every numbered element is a FIBER OCEAN line, engineered together behind the clinical front of house.
| Layer | What we deploy | Product line |
|---|---|---|
| 1. Uninterruptible power | Tower UPS from 10 to 500 kVA, modular UPS up to 1600 kVA and 1–20 kVA rack UPS for theatres, imaging and clinical IT | UPS Systems |
| 2. Battery autonomy | 48 V lithium with design life up to 15 years on the FO-LB48100, and VRLA strings sized to the autonomy the ward needs | Batteries |
| 3. Standby generation | From super-silent 55 dB at 7 m city sets to high-voltage plants of 3,300 kVA at 11 kV behind the whole campus | Diesel Generators |
| 4. Precision cooling | Room precision units holding temperature to ±1 °C and humidity to ±5%, from 7.5 to 177.2 kW, with in-row and rack-mount formats | Cooling Systems |
| 5. Clinical white space | Server and network cabinets from 6 to 47U with smart PDUs metering and switching every outlet | IT Racks & Smart PDU |
| 6. Compliance supervision | FO-MC4.0 links leak, temperature-humidity and smoke sensing, CCTV and access control on one collector | DCIM & Monitoring |
From one clinic to a health estate
The same eight layers, composed for the way care is actually delivered.
The hospital data center
Contained aisles, modular UPS and precision cooling delivered as one engineered room for PACS, EHR and the clinical core.
The server room in a cabinet
Rack UPS, rack-mount cooling, smart PDU and monitoring in one integrated cabinet for clinics and department IT closets.
The off-grid clinic
Solar, storage and generator power combined into hybrid site power that keeps rural clinics and remote health posts running while cutting diesel runtime.
Rapid-deploy field capacity
Containerized power and IT capacity, factory-built and dropped where care must stand up fast: field response and continuity sites.
Engineered for the compliance office too
The details that make the infrastructure answer to clinical engineering, facilities and audit at the same time.
Autonomy you can schedule around
Lithium strings with design life up to 15 years on the FO-LB48100 cut the battery-replacement cycles that force maintenance windows on clinical IT.
Standby the neighbours accept
Super-silent sets down to 55 dB at 7 m let full-scale standby live beside wards, clinics and residential streets.
The room that tells on itself
Leak sensing under cooling units, temperature-humidity and smoke on the same collector: the equipment room reports the problem before rounds do.
Doors with a memory
Access control and CCTV on server rooms and sensitive stores, from a line with over 1 million access control products in long-term online operation.
Fiber that respects the fire code
12 and 48 core fire-rated optical cables for risers and interconnects through occupied clinical buildings.
Every outlet accounted
Smart PDUs meter and switch per outlet, so one faulted feed in an imaging closet is isolated without touching the rest of the rack.
A night shift, fully supervised
Illustrative feed. Every event type is documented FO-MC4.0 capability: leak, temperature-humidity and smoke sensing, CCTV and access control with face capture, alarm and curve history, on one integrated collector with over 1.2 million hours MTBF.
Bring us your facility
Bed count, imaging fleet, IT load and the autonomy your clinical risk assessment demands. Our engineers return a sized power and cooling design, a supervision plan and a quotation.