DataRow in-row cooling: close to the heat source
DataRow places precision cooling directly in the row, next to the racks it protects. Variable-frequency scroll compressors and R410A refrigerant modulate cooling from 20 to 100% of capacity, improving energy efficiency over ordinary air-cooled units by 33.3 to 50%.
What this range delivers
An adaptive row-based unit for rack-level cooling in green data centers: 42U-height cabinets in 300, 600 and 900 mm widths that match cold/hot-aisle containment, with no raised floor required and N+1 redundant EC fans.
20–100% modulation
Variable-frequency scroll and EC compressors dynamically match cooling output to the actual rack heat load.
Row-native format
2000 mm (42U) cabinets in 300 / 600 / 900 mm widths slot directly into the row beside the racks.
N+1 EC fans
EC fan systems save 20 to 30% energy versus AC motors and keep airflow running through any single fan fault.
Advanced controller
7-inch touch screen, teamwork function with up to 16 remote sensors, RS485 standard, SNMP and TCP/IP optional.
DataRow Series: close-coupled row cooling
DataRow DX (007RA to 090RA)
Eleven in-row DX models from 7.5 to 90.5 kW in 300, 600 and 900 mm widths, with matched outdoor condensers and 20 to 100% capacity modulation.
DataRow CW (025RC to 065RC)
Chilled-water in-row units delivering 47.1, 76.0 and 107.6 kW at 7/12 °C water, in 300 and 600 mm widths with 42U row-matching height.
DataRow DX air-cooled: representative models
| Parameter | 007RA | 017RA | 030RA | 050RA | 090RA |
|---|---|---|---|---|---|
| Total cooling capacity | 7.5 kW | 17.8 kW | 31.5 kW | 50.5 kW | 90.5 kW |
| Air volume | 2300 m³/h | 4500 m³/h | 6000 m³/h | 10,200 m³/h | 16,200 m³/h |
| Width | 300 mm | 300 mm | 300 mm | 600 mm | 900 mm |
| Height | 2000 mm (42U) | 2000 mm (42U) | 2000 mm (42U) | 2000 mm (42U) | 2000 mm (42U) |
| Depth | 1100 mm | 1100 mm | 1100 mm | 1100 mm | 1100 mm |
| Reheat | 3.0 kW | 6.0 kW | 6.0 kW | 6.0 kW | 6.0 kW |
| Humidifier (optional) | 1.5 kg/h | 1.5 kg/h | 3 kg/h | 3 kg/h | 3 kg/h |
| Weight | 213 kg | 253 kg | 320 kg | 420 kg | 620 kg |
DataRow CW: per-model detail
| Parameter | 025RC | 045RC | 065RC |
|---|---|---|---|
| Total capacity (7/12 °C water) | 47.1 kW | 76.0 kW | 107.6 kW |
| Total capacity (10/15 °C water) | 43.2 kW | 69.6 kW | 98.6 kW |
| Air volume | 4800 m³/h | 9000 m³/h | 11,400 m³/h |
| Width | 300 mm | 600 mm | 600 mm |
| Height | 2000 mm (42U) | 2000 mm (42U) | 2000 mm (42U) |
| Reheat | 3.0 kW | 3.0 kW | 3.0 kW |
| Weight | 190 kg | 330 kg | 400 kg |
Built around a variable-frequency heart
- EC scroll compressor · Industry-leading variable displacement design, safe under load changes, long service life, low noise.
- DC frequency converter · Mature, efficient inverter control perfectly matched to compressor and controller.
- Electronic expansion valve · Fast response with real-time monitoring, matched to the self-developed valve controller.
- Oil separator · R410A-specific, anti-oxidation treated, keeps lubricating oil out of the heat exchanger.
- N+1 EC fans · Soft start, low inrush, automatic speed matching to load; airflow survives any single fan fault.
- Teamwork controller · Groups units, shares up to 16 remote temperature and humidity sensors, RS485 standard.
Where DataRow is deployed
All six cooling categories
Cooling Systems
Six cooling categories from room CRAC to immersion liquid cooling.
ExploreRoom Precision Cooling
Datacool and Cyber Master room-level CRAC units.
ExploreRack-Mount Cooling
Self-contained rack cooling for edge and telecom cabinets.
ExploreOutdoor DC Cabinet Coolers
Outdoor-rated cooling for telecom DC power cabinets.
ExploreLiquid Cooling
Direct-to-chip and rear-door liquid cooling for AI-class density.
ExploreFluid-Immersion Cooling
Immersion cabinets, TANK units and CDUs for AI-class density.
ExploreScope your In-Row Cooling
Share your heat load, site and redundancy requirements. Our engineers respond with a tailored cooling configuration.