Outdoor cabinet cooling

FO-DC outdoor cabinet air conditioners

DC-powered cabinet air conditioners delivering 600 to 3000 W of cooling directly from the −48 VDC site supply, with no inverter required. IP55 closed-loop monoblocks that keep dust and moisture away from the equipment inside outdoor enclosures.

Overview

What this range delivers

Five models sharing one platform: true DC compressors and speed-adjustable DC fans, aluminum micro-channel condensers, RAL 7035 powder-coated housings, RS485 plus dry-contact communication and a 10+ year expected service life. The flagship FO-DC3000 is rated at an EER of 11.86 BTU/W·h (T1) with a COP of 2.54 (T3).

Runs on −48 VDC

True DC compressor and fans on the 40 to 60 V site supply; no inverter, soft-start protects the site bus.

IP55 sealed loop

Closed-loop monoblock separates inside air from outside air, protecting electronics from dust and moisture.

Door-mount flange

Integrated flange for through-wall mounting on the cabinet door; plug-and-play commissioning.

Site-grade monitoring

RS485 and dry-contact alarms with auto-recovery and multi-protection functions.

The range

FO-DC Series: cabinet cooling for off-grid sites

−48 VDC

True DC operation

DC compressor and DC fans run straight from the −48 VDC site supply (40 to 60 V) with no inverter, soft-start included, drawing as little as 200 W.

IP55 monoblock

Sealed door-mount design

Closed-loop monoblock with integrated flange for through-wall mounting on the cabinet door; IP55, RAL 7035 powder-coated steel, aluminum micro-channel condenser.

Per-model detail

FO-DC Series: main specifications

ParameterFO-DC600FO-DC1000FO-DC1500FO-DC2000FO-DC3000
Cooling capacity (L35/L35)600 W1000 W1500 W2000 W3000 W
Power consumption200 W320 W500 W620 W900 W
Rated DC input current4.3 A6.7 A10.4 A11.6 A19 A
Input voltageDC 48 V (40–60 V)DC 48 V (40–60 V)DC 48 V (40–60 V)DC 48 V (40–60 V)DC 48 V (40–60 V)
Operating temperature−15 to +55 °C−15 to +55 °C−15 to +55 °C−15 to +55 °C−15 to +55 °C
RefrigerantR134aR134aR134aR134aR134a
Ingress protectionIP55IP55IP55IP55IP55
Noise level65 dB(A)65 dB(A)65 dB(A)65 dB(A)65 dB(A)
CommunicationRS485 + dry contactRS485 + dry contactRS485 + dry contactRS485 + dry contactRS485 + dry contact
Unit (H × W × D)550 × 320 × 175 mm746 × 446 × 200 mm746 × 446 × 200 mm746 × 446 × 250 mm746 × 446 × 300 mm
Net weight14.5 kg27 kg27 kg31.2 kg41 kg
Service life10+ years10+ years10+ years10+ years10+ years
ComplianceCE, RoHSCE, RoHSCE, RoHSCE, RoHSCE, RoHS
Engineering edge

Sealed, DC-native, field-proven design

  • True −48 VDC operation · DC compressor and fans run from the site battery bus; no inverter losses, no extra failure point.
  • Soft start · Prevents inrush current from disturbing site power during compressor starts.
  • Aluminum micro-channel condenser · More heat exchange in less depth, resistant to corrosion.
  • Closed-loop IP55 monoblock · Inside air never mixes with outside air; dust and moisture stay out of the cabinet.
  • Flange door mounting · Through-wall installation on the cabinet door, plug-and-play commissioning.
  • Auto-recovery protection · Multifunction alarms, RS485 and dry contacts, automatic restart after power events.
Applications

Where FO-DC cooling is deployed

Outdoor telecom cabinets
Off-grid base stations
Solar & hybrid sites

Scope your Outdoor Cabinet Air Conditioners

Share your heat load, site and redundancy requirements. Our engineers respond with a tailored cooling configuration.

Request a Quote