Liquid cooling AIDC solutions: containerized, AI-ready
Four containerized liquid-cooled data center modules, from a 20 ft edge unit to a 200 kW-per-cabinet AI cluster module: cold-plate and immersion technologies, hybrid CDU plus in-row AC cooling, and modular UPS to 1000 kVA and beyond, deployable within 7 days.
What this range delivers
Cold-plate liquid cooling with hybrid CDU and in-row AC configurations, paired with dry coolers or closed-circuit cooling towers, eliminates local hotspots and carries the ultra-high heat loads of large-scale AIDC and supercomputing clusters, with PUE as low as 1.38 and 40 to 60% higher energy efficiency than traditional air cooling.
Up to 200 kW per cabinet
Cold-plate cluster modules carry 100 kW cabinets; immersion modules carry 55 kW with 4 × 400 kW CDUs.
Hybrid cooling chain
Rack-mounted and in-row CDUs plus in-row AC, backed by dry coolers or closed-circuit cooling towers.
Mission-critical safety
N+1 core component redundancy, non-conductive coolant and multi-layer leak monitoring with water collection trays.
Deployable in 7 days
20 ft and 40 ft standard containers ship pre-integrated and plug-and-play, with Modbus/SNMP and 4G/5G remote management.
Four container modules, edge to supercomputing
Compact Module
A 20-foot containerized liquid-cooled data center for edge nodes, 5G BBU stations and small private clouds, with 300 kVA modular UPS and 15-minute lithium backup.
Cold Plate Integrated Standard Module
The 40-foot standard module pairs a 350 kW in-row CDU with 4 × 31.5 kW in-row AC and a 600 kVA modular UPS for medium data centers and enterprise AI.
100KW High-Density Cluster Module
8 × 80 kW rack-mounted CDUs plus 5 × 50.5 kW in-row AC and ≥1000 kVA modular UPS for large-scale AI training and core financial data centers.
Immersion Cooling Module
A fully immersed 40-foot data center with 4 × 400 kW in-row CDUs for blockchain, ultra-high-density AI clusters and supercomputing.
Main specifications by module
| Parameter | 20FT Compact Module | 40ft Cold Plate Standard | 100KW Cluster Module | Immersion Cooling (40 ft) |
|---|---|---|---|---|
| Liquid cooling technology | Cold plate | Cold plate | Cold plate | Immersion |
| Certification | CE, ISO | CE, ISO | CE, ISO | CE, ISO |
| Container (W × D × H) | 3200 × 6500 × 3500 mm | 3200 × 12192 × 3800 mm | 3200 × 12800 × 3800 mm | 3200 × 12192 × 3800 mm |
| Power density per cabinet | 50 kW | 50 kW | 100 kW | 55 kW |
| Cooling configuration | Dry cooler / closed-circuit cooling tower | 350 kW in-row CDU + 4 × 31.5 kW in-row AC | 8 × 80 kW rack-mounted CDU + 5 × 50.5 kW in-row AC | 4 × 400 kW in-row CDU |
| Air-to-liquid ratio | 1:9 | – | – | – |
| UPS capacity | 300 kVA modular UPS | 600 kVA modular UPS | ≥1000 kVA modular UPS | – |
| Battery configuration | 1 set of 512 V 100 Ah lithium (15-minute backup) | – | – | – |
| Safety features | Full-link leak detection, water collection tray, non-toxic coolant | – | – | – |
| Communication | Modbus / SNMP, 4G/5G wireless | – | Modbus / SNMP | – |
| Applicable scenarios | Edge computing nodes, 5G BBU stations, remote data centers, small private clouds | Medium data centers, enterprise AI, hybrid computing clusters | Large-scale AI training clusters, supercomputing centers, core financial data centers | Blockchain mining, ultra-high-density AI clusters, supercomputing |
A complete data center in one module
- Integrated cluster deployment · 40 ft standard containers ship as pre-integrated cluster modules, plug-and-play, enabling rapid on-site commissioning for large-scale projects.
- Hybrid thermal chain · Rack-mounted or in-row CDUs handle the liquid loop while in-row AC absorbs the residual air load, eliminating local hotspots completely.
- Closed-circuit heat rejection · Dry coolers or closed-circuit cooling towers reject heat outdoors with an air-to-liquid ratio down to 1:9.
- Uninterrupted power · Modular UPS from 300 kVA to ≥1000 kVA with customizable external lithium battery packs (15-minute backup on the compact module).
- Multi-layer protection · N+1 core components, non-conductive coolant, full-link leak detection and water collection trays.
- Intelligent remote management · Modbus/SNMP with 4G/5G wireless support for real-time monitoring of operating status and remote maintenance.
Ready for density computing
Where AIDC liquid cooling is deployed
Scope your Liquid Cooling AIDC Solution
Share your heat load, site and redundancy requirements. Our engineers respond with a tailored cooling configuration.