Skip to content
Diesel Generators · FAWDE

FAWDE-powered generators: 10 to 413 kVA

FOGEN value-line sets on Chinese FAWDE engines with Smartgen HGM6110 or HGM6120 controllers with AMF, in open and silent builds at 50 and 60 Hz.

Overview

What this range delivers

Thirty-four build variants: 8 to 300 kW prime with FOGEN alternators, CHINT MCCB breakers and 8-hour base tanks.

8 to 300 kW prime

YD385D to 6DN1J FAWDE engines at 50 and 60 Hz.

Smartgen HGM6110U

AMF controller standard; HGM6120 on option.

🛡

Made in China

First Auto Works diesel engines with wide parts availability.

📦

Open or silent

Cost-efficient open frames or weatherproof canopies.

Open set

Open-frame sets

Green FAWDE blocks with white controller cabinets on skid frames.

Silent canopy

Silent sets

Compact canopies for street-side and rooftop standby.

The range · 50 Hz

FAW 50 Hz, three phase

ModelPrime kW / kVAStandby kW / kVAEngineFOGEN alternatorOpen set L×W×H mmkg (open)Silent L×W×H mmkg (silent)
FGLL-118 / 108.8 / 11YD385DWHI164B1450×650×11004001800×850×1100600
FGLL-1510.8 / 13.512 / 154DW81-23DWHI164C1500×650×11004302000×850×1200630
FGLL-16.512 / 1513 / 164DW81-23DWHI164D1500×650×11004502000×850×1200650
FGLL-2216 / 2017.6 / 224DW91-29DWHI184E1500×650×11005002000×850×1200750
FGLL-27.520 / 24.522 / 27.54DW92-35DWHI184F1550×650×11005502000×850×1200750
FGLL-3324 / 3026.5 / 334DW92-39DWHI184G1900×800×12506202500×950×1510830
FGXL-4030 / 3833 / 414DX21-53D/39-43kwWHI184H1900×800×13508502500×950×15101350
FGXL-5540 / 5044 / 554DX22-65D/48-53kwWHI224D1900×800×14009002500×950×15101400
FGXL-7050 / 6355 / 694DX23-78D/57-63kwWHI224E1900×800×14009503100×1100×16101500
FGXL-9670 / 8877 / 964DF2-12D/84-92kwWHI224G2000×800×145010003100×1100×16101600
FGXL-11080 / 10088 / 1106DF2D-14D/96-105kwWHI274C2300×850×155010503100×1200×16101700
FGXL-138100 / 125110 / 1386DF2-17D/125-138kwWHI274ES2400×900×155014003100×1200×16102200
FGXL-165120 / 150132 / 1656DF2-19D/150-165kwWHI274F2500×1000×155016003600×1200×20502300
FGXL-206150 / 188165 / 2066DL1-24D/176-194kwWHI274G2800×1000×160017004200×1400×20002500
FGXL-248180 / 225198 / 2486DL2-27D/205-226kwWHI274J2800×1000×160018004200×1400×20002700
FGXL-275200 / 250220 / 2756DL2-30/227-251kwWHI274K3100×1000×160021004200×1400×20003000
FGXL-330240 / 300264 / 3306DM2J-39D/287-316kwWHI4D3100×1000×160022004200×1400×20003200
FGXL-413300 / 375330 / 4136DN1J-45D/332-365kwWHI4F3200×1000×165026004200×1400×20003600
The range · 60 Hz

FAW 60 Hz, three phase

ModelPrime kW / kVAStandby kW / kVAEngineFOGEN alternatorOpen set L×W×H mmkg (open)Silent L×W×H mmkg (silent)
FGLL-1410 / 1311 / 14YD385DWHI164B1450×650×11004001650×800×1150700
FGLL-2115 / 1917 / 214DW81-28DWHI164D1650×650×11005001900×830×1150800
FGLL-3022 / 2824 / 304DW91-38DWHI184E1700×650×11005502000×830×1150900
FGLL-3425 / 3128 / 344DW92-42DWHI184F1900×800×12506202200×950×13001000
FGLL-4130 / 3833 / 414DX21-53DWHI184G1800×800×12508502280×950×13001050
FGLL-4835 / 4439 / 484DX22-60DWHI184H1900×800×14009002280×950×13001200
FGXL-6648 / 6053 / 664DX23-82DWHI224D1900×800×14009503100×1100×16101300
FGXL-8565 / 8172 / 85CA4110/125Z-11DWHI224F2000×800×145010003100×1100×16101500
FGXL-11785 / 10694 / 117CA4DF2-14DWHI274C2300×850×155010503100×1200×16102000
FGXL-13195 / 119105 / 131CA6DF2D-16DWHI274C2300×850×155010503100×1200×16101700
FGXL-151110 / 138121 / 151CA6DF2-18DWHI274D2400×900×155014003100×1200×16102200
FGXL-179130 / 163143 / 179CA6DF2-21DWHI274E2500×1000×155016003600×1200×20502300
FGXL-22727 / 34182 / 227CA6DL1-27DWHI274G2800×1000×160017004200×1400×20002500
FGXL-275200 / 250220 / 275CA6DL2-32DWH274H3100×1000×160021004200×1400×20003000
FGXL-370270 / 338297 / 371CA6DM2J-42DWHI4D3100×1000×160021004200×1400×20003000
FGXL-413300 / 375330 / 413CA6DN1J-46DWHI4ES3200×1000×165026004200×1400×20003600

All ratings follow ISO 8528 and ISO 3046: prime power allows 10% overload for one hour in every twelve; standby power covers up to 500 hours per year with no overload. Refer to the model datasheet for final ratings. Controller: Smartgen HGM6110U across the range. FOGEN alternators as standard.

Inside the set

Value engineering without shortcuts

  • FAWDE engine · First Auto Works diesel platforms from YD385D to 6DN1J-45D.
  • Smartgen controller · HGM6110 with AMF as standard, HGM6120 on option.
  • CHINT MCCB · Moulded-case breaker protection as standard.
  • Vibration isolators · Between engine, alternator and base.
  • 8-hour base tank · Steel base frame with forklift holes and drainage.
  • Options · ATS, paralleling, battery charger, water-jacket preheater, oil heater and double air cleaner.
In the field

FAWDE sets as delivered

Factory test bay

Open set on test in front of finished canopies.

Silent canopy

Weatherproof enclosure on a site apron.

Applications

Where FAWDE sets are deployed

Telecom sites
Data centers
Hospitals & buildings
Industry & oil field

Scope your FAWDE generator set

Share your load, voltage and site conditions. Our engineers confirm the right FAWDE model and options with a formal quotation.

Request a Quote