UPS Systems

Tower UPS

A standalone online double-conversion tower UPS from 1 kVA single-phase to 500 kVA three-phase, engineered to VFI-SS-111 with 0 ms transfer, high efficiency and parallel expansion for enterprise rooms, telecom sites and data-center loads.

Key applications: data-center and server rooms, telecom and network sites, banking and enterprise, healthcare.

Key features

Why Tower UPS

Online double-conversion

Pure online (VFI) topology to VFI-SS-111 with 0 ms transfer between mains, battery and bypass for clean, uninterrupted output.

1 kVA to 500 kVA

Single-phase 1–10 kVA and three-phase 10–500 kVA units cover everything from a comms room to a data hall.

Parallel & expandable

Parallel operation of up to 6 units with shared battery banks and LBS synchronization for capacity and redundancy.

High efficiency

Up to 96% online efficiency and ECO mode up to 99%, with input power factor >0.99 and current THD <3%.

Specifications

Capacity line-up

ModelRated capacityPhase
FO-TUPS-11011 kVA / 1 kWSingle-phase
FO-TUPS-11033 kVA / 3 kWSingle-phase
FO-TUPS-11066 kVA / 6 kWSingle-phase
FO-TUPS-111010 kVA / 10 kWSingle-phase
FO-TUPS-331010 kVA / 10 kWThree-phase
FO-TUPS-3303030 kVA / 30 kWThree-phase
FO-TUPS-335050 kVA / 50 kWThree-phase
FO-TUPS-3306060 kVA / 60 kWThree-phase
FO-TUPS-33100100 kVA / 100 kWThree-phase
FO-TUPS-33200200 kVA / 200 kWThree-phase
FO-TUPS-33300300 kVA / 300 kWThree-phase
FO-TUPS-33500500 kVA / 500 kWThree-phase

Additional ratings (2, 15, 20, 40, 80, 120, 150, 250, 400 kVA) and long-backup versions are available; high-frequency (unity PF) and transformer-based configurations are selected per project.

Common parameters

System & electrical

ParameterValue
TopologyOnline double-conversion (VFI-SS-111)
Input voltage380 / 400 / 415 VAC (3-phase); 220 / 230 / 240 VAC (single-phase)
Input voltage range285–520 VAC (3-phase, full load)
Input frequency40–70 Hz
Input power factor>0.99
Input current THD<3%
Output voltage380 / 400 / 415 VAC (3-phase); 220 / 230 / 240 VAC (single-phase)
Output frequency50 / 60 Hz
Output voltage accuracy±1%
Output THD≤1% (linear load), ≤3% (non-linear load)
Output power factor1.0 (unity; 0.9 on LF variants)
Transfer time0 ms (mains ↔ battery, inverter ↔ bypass)
System efficiencyUp to 96% (online); up to 99% (ECO mode)
Overload capacity110% for 60 min; 125% for 10 min; 150% for 1 min
Parallel operationUp to 6 units, shared battery, LBS synchronization
Battery12 V blocks: 2–8, 16–20 or 32–44 cells; VRLA or LiFePO4
DisplayLCD + LED colour touch screen
CommunicationRS232, RS485, dry contact, SNMP (optional), EPO
Protection levelIP20
Operating temperature0°C to 40°C
Relative humidity0–95% non-condensing
MTBF>200,000 h

Specifications reflect the FIBER OCEAN FO-TUPS datasheet. Exact ratings vary by model; regional configuration and options are confirmed per project.