UPS Systems

Modular UPS

A hot-swappable modular UPS from 10 kVA to 1.6 MW with no-master-slave parallel and N+1 redundancy, up to 97% efficiency, engineered for data centers and mission-critical loads that grow over time.

Key applications: data centers and colocation, government and mega projects, banking and enterprise, large telecom sites.

Key features

Why Modular UPS

Hot-swap modular

Hot-swappable power modules let you scale capacity and service the system without shutting down critical loads.

10 kVA to 1.6 MW

One frame family scales from 10 kVA edge cabinets to 1.6 MW (1600 kVA) data-hall systems by adding 30 / 50 / 100 kW power modules.

N+1 redundancy

No-master-slave parallel with N+1 module redundancy keeps the load protected through any single module fault.

Up to 97% efficiency

Up to 97% online efficiency and ECO mode up to 99% cut energy losses and cooling demand at scale.

Specifications

Capacity line-up

ModelSystem capacityPower module
FO-MUPS-331010 kVASmall-modular
FO-MUPS-338080 kVASmall-modular
FO-MUPS-33120120 kVA30 kW modules
FO-MUPS-33300300 kVA50 kW modules
FO-MUPS-33600600 kVA50 / 100 kW modules
FO-MUPS-33800800 kVA100 kW modules
FO-MUPS-3310001000 kVA (1 MW)100 kW modules
FO-MUPS-3316001600 kVA (1.6 MW)100 kW modules

Built from 30 / 50 / 100 kW hot-swap power modules; intermediate system capacities and long-backup versions are available, and frame size, module rating and redundancy are configured per project.

Common parameters

System & electrical

ParameterValue
TopologyOnline double-conversion, modular hot-swap
Input voltage380 / 400 / 415 VAC (3-phase + N + PE)
Input voltage range138–485 VAC
Input frequency40–70 Hz
Input power factor>0.99
Input current THD<3%
Output voltage380 / 400 / 415 VAC (3-phase)
Output frequency50 / 60 Hz
Output voltage accuracy±1%
Output THD<1% (linear load), ≤3% (non-linear load)
Output power factor1.0 (unity)
Transfer time0 ms (mains ↔ battery, inverter ↔ bypass)
System efficiencyUp to 97% (online); ≥99% (ECO mode)
Overload capacity110% for 60 min; 125% for 10 min; 150% for 1 min; 200% to bypass
Parallel operationNo-master-slave, N+1 redundancy, up to 8 units
BatterySealed lead-acid or LiFePO4; shared or per-frame banks
Display7-inch colour touch LCD + LED
CommunicationRS232, RS485, dry contact, MODBUS, SNMP (optional), EPO
Protection levelIP20
Operating temperature0°C to 40°C
Relative humidity0–95% non-condensing

Specifications reflect the FIBER OCEAN FO-MUPS Series datasheet. Exact ratings vary by model; regional configuration and options are confirmed per project.

Applications
Data CentersGovernment & Mega ProjectsBanking & EnterpriseTelecom & 5G
Inquire

Request a quote for FIBER OCEAN Modular UPS

Share your load, backup duration and redundancy requirements. Our engineers respond with a tailored configuration and pricing.