UPS Systems

Rack UPS

A rack-mountable online double-conversion UPS from 1 kVA to 60 kVA in a compact 19-inch chassis, with shared-battery parallel operation and an intelligent SNMP slot, for cabinets, edge sites and network rooms.

Key applications: data-center and network cabinets, telecom and edge sites, banking and enterprise IT rooms.

Key features

Why Rack UPS

Online double-conversion

Pure online (VFI) topology with 0 ms transfer isolates rack loads from sags, surges, frequency drift and outages.

1 kVA to 60 kVA

Single-phase 1–20 kVA and three-phase 10–60 kVA in a compact 19-inch rack-mount chassis.

Parallel & shared battery

Parallel operation of multiple units with shared battery banks and LBS synchronization for capacity and N+1 redundancy.

Smart slot & monitoring

Intelligent SNMP slot with RS232 and USB brings each UPS into DCIM, BMS and remote-monitoring platforms.

Specifications

Capacity line-up

ModelRated capacityPhase
FO-RUPS-11011 kVA / 1 kWSingle-phase
FO-RUPS-11022 kVA / 2 kWSingle-phase
FO-RUPS-11033 kVA / 3 kWSingle-phase
FO-RUPS-11066 kVA / 6 kWSingle-phase
FO-RUPS-111010 kVA / 10 kWSingle-phase
FO-RUPS-331010 kVA / 10 kWThree-phase
FO-RUPS-332020 kVA / 20 kWThree-phase
FO-RUPS-333030 kVA / 30 kWThree-phase
FO-RUPS-334040 kVA / 40 kWThree-phase
FO-RUPS-3306060 kVA / 60 kWThree-phase

Intermediate ratings and long-backup versions are available; unity-PF (high-frequency) configurations are selected per project.

Common parameters

System & electrical

ParameterValue
TopologyOnline double-conversion (VFI)
Form factor19-inch rack-mountable chassis
Input voltage220 / 230 / 240 VAC (single-phase); 380 / 400 / 415 VAC (3-phase)
Input frequency40–70 Hz
Input power factor≥0.99
Input current THD<5% (linear load)
Output frequency50 / 60 Hz
Output voltage accuracy±1%
Output power factor0.9 (up to 1.0 on unity variants)
Transfer time0 ms (mains ↔ battery, inverter ↔ bypass)
System efficiencyUp to 95.5% (online); up to 98.5% (ECO mode)
Overload capacity110% for 60 min; 125% for 10 min; 150% for 1 min
Parallel operation3+ units, shared battery, LBS synchronization
Battery12 V blocks: 2–8, 16–20 or 32–44 cells; internal or external bank; VRLA or LiFePO4
DisplayLCD + LED status indicators
CommunicationRS232, USB; SNMP slot (optional), dry contact, EPO
Protection levelIP20
Operating temperature0°C to 40°C
Relative humidity0–95% non-condensing

Specifications reflect the FIBER OCEAN FO-RUPS datasheet. Exact ratings vary by model; regional configuration and options are confirmed per project.