Skip to content
Insights · AquaCore Data Centers

Micro data center solutions: a full data center at cabinet scale

A micro data center solution is not a small server rack with a UPS bolted on. It is a whole data center’s disciplines, power, cooling, fire suppression and monitoring, engineered into a single sealed enclosure that stands wherever IT lives without a room of its own.

What counts as a micro data center

Integrated, not assembled on site

The difference between a micro data center and a server closet is not size, it is discipline. FIBER OCEAN’s AquaCore I-Rack integrates UPS, cooling, racks, distribution, fire suppression and monitoring in one enclosure, tested before it ships, rather than assembled from separate boxes after delivery.

The same platform runs from the single-cabinet EC20 to the five-cabinet ER05 row build, so the discipline scales with the site instead of being re-engineered at each step.

FIBER OCEAN AquaCore I-Rack micro data center cabinet
Inside the cabinet

Seven layers behind one door

Every numbered element is a FIBER OCEAN product line, integrated before the cabinet ships.

LayerWhat is deployedProduct line
1. The cabinetIP5X fully enclosed, closed cold / hot isolation, single-cabinet EC20 to five-cabinet ER05AquaCore Micro DC Series
2. Rack UPS3–30 kVA, rack-mountable, 2N architecture, ultra-wide voltage inputUPS Systems
3. Battery ride-through15 to 120 minutes, configurable to the site’s risk assessmentBatteries
4. Close-coupled cooling3.5 up to 2×12.5 kW, ±0.5 °C, inverter compressors, dual EC fans, N+XRack-Mount Cooling
5. White spaceUp to 30U integrated; row builds add up to four 42U IT cabinets with smart PDUsIT Racks & Smart PDU
6. Fire suppressionOptional heptafluoropropane 1U gas suppression, Class C lightning protectionAquaCore Data Centers
7. Monitoring10-inch HMI watching UPS, distribution, cooling, leakage, temperature-humidity, smoke and doorDCIM & Monitoring
Key numbers buyers ask for

The specifications that decide fit

⚡

≤1.4 PUE

At cabinet scale, from 2N power architecture and N+X cooling redundancy engineered together, not bolted together.

❄

±0.5 °C cooling accuracy

Close-coupled cooling with inverter compressors and dual EC fans in N+X, plus anti-condensation control at low load.

🔊

≤49 dB noise

Quiet enough to stand in an open office, not just a plant room, with closed cold / hot isolation inside the cabinet.

🔋

15–120 min ride-through

Battery backup configured to the site’s risk assessment, not fixed to whatever fits the shelf.

Where they get deployed

Wherever IT lives without a room of its own

The same cabinet, configured for the place it stands.

🏦

Branch & clinic

One integrated cabinet replaces the shelf of adapters behind the door, sealed, cooled, backed up and monitored.

💼

Open office

At or under 49 dB with closed cold / hot isolation, the data center stands in the workspace itself.

📈

Growing site

Start with a single cabinet; row builds carry up to four additional 42U IT cabinets on the same cooling and power spine.

🌐

Distributed estate

Hundreds of branches, one design, every cabinet’s touchscreen reporting to the same operating center.

Sizing the build

Single cabinet, or a row that grows

The AquaCore I-Rack platform spans from a single sealed cabinet to a five-cabinet row on the same power and cooling spine, so the starting size does not lock in the ceiling.

FAQ

Frequently asked questions

What is included inside a FIBER OCEAN micro data center?

UPS, cooling, racks, distribution, fire suppression and monitoring, integrated and tested in one enclosure before delivery.

How much battery backup does a micro data center provide?

15 to 120 minutes of ride-through, configurable to the site’s risk assessment.

How quiet is a micro data center cabinet?

49 dB or quieter, low enough to stand in an open office.

Can a micro data center grow after installation?

Yes. Row builds carry up to four additional 42U IT cabinets on the same cooling and power spine, from the single-cabinet EC20 up to the five-cabinet ER05.

What PUE does a micro data center achieve?

Up to 1.4 PUE at cabinet scale, from 2N power architecture and N+X cooling redundancy engineered together.

Scope your micro data center

Send us your edge load and site constraints, and our engineers will confirm the right cabinet build.

Request a Quote