Floor-standing −48 V DC power plants up to 3000 A (FO-DC-483000) and a 4000 A dual-rack flagship, two paralleled 2000 A racks delivering 224 kW at ≥ 96.6% efficiency with N+1 redundancy, engineered for central offices, hyperscale data centers and large network cores.

Key applications: central offices, hyperscale data centers, large network cores, national telecom hubs.

Key features

Why large-capacity DC

1000 A to 4000 A

Floor-standing cabinets up to 3000 A (FO-DC-483000) and a 4000 A dual-rack system built from two paralleled 2000 A racks.

224 kW, N+1 redundant

The 4000 A flagship carries 2 × 28 × RM4875 (75 A) hot-swap modules, N+1 redundant per rack, for 224 kW installed.

Three-phase input

85–300 Vac three-phase input with DELIXI AC distribution and protection on the flagship.

≥ 96.6% efficiency

High conversion efficiency at scale to cut energy and cooling load in central offices and data halls.

Specifications

Capacity line-up

ModelNominal output currentFormat
FO-DC-4810001000 AFloor-standing cabinet
FO-DC-4812001200 AFloor-standing cabinet
FO-DC-4815001500 AFloor-standing cabinet
FO-DC-4818001800 AFloor-standing cabinet
FO-DC-4820002000 AFloor-standing cabinet
FO-DC-4830003000 AFloor-standing, 600×600×2000 mm
4000 A System4000 A (2 × 2000 A)Dual racks, 600×600×2200 mm, RAL 9005

Model numbers encode nominal 48 V output current. Per-model cabinet dimensions, module counts and options are confirmed on the official datasheet.

Common parameters

System & electrical

ParameterValue
System voltage48 V DC nominal (−48 V)
Nominal output current1000–4000 A (4000 A = 2 × 2000 A paralleled racks)
System powerUp to 224 kW installed (4000 A system)
Rectifier modulesRM4875 (75 A), hot-swap, N+1 redundant per rack; up to 2 × 28 modules (4000 A dual-rack)
Module power factor≥0.99
AC input85–300 Vac, three-phase
AC distributionDELIXI AC distribution and protection
EnclosureFloor-standing cabinet(s), RAL 9005, front-access service (dual 600×600×2200 mm racks on the 4000 A system)
Peak efficiency≥95–96.6%
ControllerMCU-SM32Z, LCD, RS232 / RS485, SNMP, dry-contact alarms
Battery managementLLVD / BLVD disconnect, temperature-compensated charging, battery test
ProtectionClass C SPD, input / output breakers, over- / under-voltage and over-temperature shutdown
ComplianceEngineered to IEC, ETSI and Telcordia requirements

Values span the 1000–4000 A range; variable items are shown as ranges and fixed items apply across the line. Per-model ratings, cabinet dimensions and module counts are confirmed on the official datasheet.

Applications
Central officesHyperscale data centersNetwork coresGovernment & Mega Projects